Exit Zen
111
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.37-1/PresetStatusParameterWrapper.cs:13
This parameter is used to determine if a preset scene is programmed and to retrieve the timing information stored with that scene (Get). It also allows a preset scene to be cleared or to change the timing information stored with that scene (Set).
112
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.37-1/LockPinParameterWrapper.cs:10
Lock PIN
113
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.37-1/LockPinParameterWrapper.cs:12
This parameter is used to get and set the PIN code for devices that support locking. The lock state is set using the Lock State message. The PIN format depends on the capabilities of the device.
114
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.37-1/CurveParameterWrapper.cs:10
Curve
115
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.37-1/CurveParameterWrapper.cs:12
Sometimes called dimmer laws, curves set a relationship between the control level and the output level. This is useful when matching different loads, or when matching different dimmer types. On more advanced dimmers, it may be possible to program user-defined curves. Transferring user defined curve data is beyond the scope of DMXControl 3.
116
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.37-1/OutputResponseTimeDescriptionParameterWrapper.cs:11
Output Response Time Description
117
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.37-1/ModulationFrequencyParameterWrapper.cs:11
Modulation Frequency
118
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.37-1/ModulationFrequencyParameterWrapper.cs:12
This parameter is used to get and set the modulation frequency for devices that support adjustment of the modulation frequency of their output.
119
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.37-1/DimmerInfoParameterWrapper.cs:10
Dimmer Info
120
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.37-1/DimmerInfoParameterWrapper.cs:11
This parameter is used to retrieve a variety of dimmer related information that describes the capabilities of the dimmer.
121
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.37-1/PowerOnSelfTestParameterWrapper.cs:10
Power-On Self Test
122
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.37-1/PowerOnSelfTestParameterWrapper.cs:12
This parameter is used to get or set the Power-On Self Test mode parameter. This allows devices to enable or disable a power-on self test mode that executes automatically on power up.
123
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.37-1/IdentifyModeParameterWrapper.cs:10
Identify Mode
124
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.37-1/IdentifyModeParameterWrapper.cs:11
This parameter allows devices to have different Identify Modes for use with the Identify Device message.
125
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.37-1/DMX512FailModeParameterWrapper.cs:10
DMX512 Fail Mode
126
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.37-1/DMX512FailModeParameterWrapper.cs:12
This parameter defines the behavior of the device when the DMX512 control signal is lost. A scene that is triggered by a DMX512 Loss of Signal condition usually ignores the Wait Time stored using the CAPTURE_PRESET PID and instead use the Hold Time included with this PID.
127
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.37-1/LockStateParameterWrapper.cs:10
Lock State
128
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.37-1/LockStateParameterWrapper.cs:12
This parameter is used to determine the lock state for devices that support locking. A lock, when applied, can provide a variable level of access/change protection. The locking mechanism is designed to deter tampering and is not intended to provide absolute security.
129
../DMXLIB/RDM/ParameterWrapper/Catalogue/Manufacturer/SGM/SMPSCalibrationParameterWrapper.cs:10
SMPS Calibration
130
../DMXLIB/RDM/ParameterWrapper/Catalogue/Manufacturer/SGM/SMPSCalibrationParameterWrapper.cs:11
This parameter is used to recalibrate the SMPS.