Exit Zen
178
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.20/ManufactorLabelParameterWrapper.cs:12
This parameter provides an ASCII text response with the Manufacturer name for the device of up to 32 characters.
179
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.20/CapturePresetParameterWrapper.cs:10
Capture Preset
180
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.20/CapturePresetParameterWrapper.cs:11
This parameter is used to capture a static scene into a Preset within the responder. Upon receipt of this parameter the responder will capture the scene and store it to the designated preset. Fade and Wait times for building sequences may also be included. Times are in tenths of a second. When timing information is not required it is set to 0x00. The Up Fade Time is the fade in time for the current scene and the Down Fade Time is the down fade for the previous scene or active look. The Wait Time is the time the device spends holdingthe current scene before proceeding to play the next scene when the presets are being played back as a sequence.
181
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.20/ClearStatusIDParameterWrapper.cs:10
Clear Status ID
182
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.20/ClearStatusIDParameterWrapper.cs:11
This parameter is used to clear the status message queue.
183
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.20/ResetDeviceParameterWrapper.cs:10
Reset Device
184
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.20/ResetDeviceParameterWrapper.cs:11
This parameter is used to instruct the responder to reset itself. This parameter also clears the Discovery Mute flag. A cold reset is the equivalent of removing and reapplying power to the device.
185
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.20/DevicePowerCyclesParameterWrapper.cs:10
Device Power Cycles
186
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.20/DevicePowerCyclesParameterWrapper.cs:12
This parameter is used to retrieve or set the number of Power-up cycles for the device. Some devices may only support the retrieval of this parameter and not allow the device’s power - up cycles to be set.
187
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.20/DeviceInfoParameterWrapper.cs:10
Device Info
188
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.20/DeviceInfoParameterWrapper.cs:12
This parameter is used to retrieve a variety of information about the device that is normally required by a controller.
189
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.20/RecordSensorsParameterWrapper.cs:10
Record Sensors
190
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.20/RecordSensorsParameterWrapper.cs:11
This parameter instructs devices such as dimming racks that monitor load changes to store the current value for monitoring sensor changes.
191
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.20/SlotInfoParameterWrapper.cs:12
Slot Info
192
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.20/SlotInfoParameterWrapper.cs:14
This parameter is used to retrieve basic information about the functionality of the DMX512 slots used to control the device. The response is a packed list of Slot Label ID’s referencing into the Slot Labels table.
193
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.20/PerformSelfTestParameterWrapper.cs:10
Perform Self Test
194
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.20/PerformSelfTestParameterWrapper.cs:12
This message is used to execute any built in Self-Test routine that may be present. The test may run continuously until receiving a message with a SELF_TEST_OFF value, or may exit upon completion.
195
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.20/DMX512PersonalityParameterWrapper.cs:10
DMX512 Personality
196
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.20/DMX512PersonalityParameterWrapper.cs:12
This parameter is used to set the responder’s DMX512 Personality. Many devices such as moving lights have different DMX512 “Personalities”. Many RDM parameters may be affected bychanging personality.
197
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.20/ProxiedDevicesCountParameterWrapper.cs:11
Proxied Devices Count