Exit Zen
94
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.37-1/BurnInParameterWrapper.cs:10
English
Burn-In
95
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.37-1/BurnInParameterWrapper.cs:12
English
This parameter provides a mechanism for devices that require specified burn-in times. In order for fluorescent lamps to operate properly with all types of fluorescent dimming ballasts they must be operated continuously at full output for a manufacturer recommended period of time (BURN_IN). This parameter allows users to set a burn-in time for dimmers controlling fluorescent ballasts after changing lamps.
96
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.37-1/OutputResponseTimeParameterWrapper.cs:10
English
Output Response Time
97
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.37-1/OutputResponseTimeParameterWrapper.cs:12
English
Dimmers often have a variable response time that smoothes fades that might otherwise exhibit a stepping behavior between levels. The consequence of smoothing fades using this method is that the dimmer may not turn on or off as quickly as it would without the slowed response. Dimmers with variable response times allow the user to achieve a balance between speed and smoothness in fades.
98
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.37-1/PresetMergeModeParameterWrapper.cs:10
English
Preset Merge Mode
99
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.37-1/PresetMergeModeParameterWrapper.cs:12
English
Normally a preset started with the PRESET_PLAYBACK message has priority over a DMX512 input signal. On some devices this may not be the desired effect, and other merge modes may be offered. This parameter is used to retrieve or change the preset merge mode.
100
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.37-1/LockStateDescriptionParameterWrapper.cs:11
English
Lock State Description
101
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.37-1/LockStateDescriptionParameterWrapper.cs:13
English
This parameter is used to get a descriptive ASCII text label for a given lock state. The label may be up to 32 characters.
102
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.37-1/MinimumLevelParameterWrapper.cs:10
English
Minimum Level
103
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.37-1/MinimumLevelParameterWrapper.cs:12
English
Minimum Level sets the lowest level that the output may go to in response to the control signal - DMX512, Preset Playback or otherwise. By setting the On Below Minimum value, this can be used to provide Preheat functionality for incandescent lamps.
104
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.37-1/CurveDescriptionParameterWrapper.cs:11
English
Curve Description
105
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.37-1/CurveDescriptionParameterWrapper.cs:13
English
This parameter is used to get a descriptive ASCII text label for a given Curve number. The label may be up to 32 characters.
106
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.37-1/PresetInfoParameterWrapper.cs:10
English
Preset Info
107
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.37-1/PresetInfoParameterWrapper.cs:11
English
This parameter is used to retrieve a variety of preset related information that describes the preset capabilities of the device.
108
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.37-1/MaximumLevelParameterWrapper.cs:10
English
Maximum Level
109
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.37-1/MaximumLevelParameterWrapper.cs:12
English
Maximum Level sets the highest level that the output may go to in response to the control signal - DMX512, Preset Playback or otherwise. This can be used to provide Topset functionality.
110
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.37-1/PresetStatusParameterWrapper.cs:11
English
Preset Status
111
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.37-1/PresetStatusParameterWrapper.cs:13
English
This parameter is used to determine if a preset scene is programmed and to retrieve the timing information stored with that scene (Get). It also allows a preset scene to be cleared or to change the timing information stored with that scene (Set).
112
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.37-1/LockPinParameterWrapper.cs:10
English
Lock PIN
113
../DMXLIB/RDM/ParameterWrapper/Catalogue/E1.37-1/LockPinParameterWrapper.cs:12
English
This parameter is used to get and set the PIN code for devices that support locking. The lock state is set using the Lock State message. The PIN format depends on the capabilities of the device.